Cessna Service Bulletin SB08-34-02
Alternate Static Source Selector Valve Inspection
See SB for a/c effected.
Effects: 172R, 172S, 182S, 182T, T182T, 206H and T206H that had an alternate static source selector valve pn# 2013142-18 replaced between 20 Nov 07 thru 18 Feb 08. Reason: To confirm that the alternate static port located on the alternate static source valve is not restricted by a part number placard.
Compliance: Mandatory
- For IFR conditions: shall be accomplished prior to further flight
- For VFR conditions: shall be accomplished at the next scheduled inspection, within the next 100 hours of operation or 4 months, whichever occurs first.
CREDIT EXPIRATION DATE: 30 Sep 08
NOTE: Service Bulletins considered mandatory, by the CAP Service Bulletin Committee, and Service Bulletins marked mandatory by the manufacturer, with a credit date, will be posted on this page and distributed to the appropriate Wings.